New:

  • Support for encrypted HAN, which enables Danish HAN meter connectivity
  • Support for danish HAN message structure
  • Preliminary support for Eastron SDM120(CTM)

Fixed:

  • Fix accumulated energy decoding for Swedish P1 meters
  • Fix for Kamstrup 685-* ARON / IT CT-connected meters
  • Fixed corrupted timestamps on OTA commands
  • Fix for Modbus errors on P1 Equalizer
  • Fix for violation on interframe gaps on Modbus
  • Fix for current directions on Aidon P1 meters with PV
  • Fix for non-standards compliant Star STZ 351 P1 meters (edited)

Improved:

  • Made P1 parser more robust
  • Improvements to HAN solar current direction detection
  • Workaround for accumulated energy being off by x10 on some Swedish Aidon HAN meters